Containers
   
Example: Quick Steam Generator in 40 ft. Container


40 ft. standard container

  • 2 double wing doors (front and back) for
    service and repair of components or
  • side door ca. 1.000 x 2.000 mm
  • steel bottom


  • steam accumulator
    type GDS 1400, content 1,2 m³

  • feedwater tank 2.200 liters
    including fittings and pre-heating
    (deaeration)
equipped with
  • quick steam generator, system GEKA-Heat
    Technology, type SDE-Z 2600,
    steam capacity 2.600 kg/h, 10 bars
  • diesel oil burner

    
  • water treatment: dosing equipment
    and double water softener
  • diesel tank 1.500 liters
  • diesel power generator
  • chimney
  • switchboards with AC

   
 
  
Scope of Delivery:
All a. m. components of the steam boiler installation are mounted and connected ready for operation.
The container is equipped with lighting installation. The body of the container is equipped with 2
doors. This enables service, repair or replacement of single components
without removing other or all components.

The emergency generator provides operation without external electric power. The chimney is designed
in modular system and consists of several pieces. They can be lifted on the roof of the container easily -
without special devices. Assembly of the pieces via flange and plug-in system.

The container can be transported on truck and moved with usual
cranes and elevators for shipment.
  
Steps for Operation:
1. Mounting of chimney.
2. Connection for steam exit (outside steam piping by customer)
3. Connection for water supply
4. Filling of diesel tank
5. Checking of water treatment